Correo electrónico:[email protected]


Producto

2
3

TSD01-01Two Way Push Pull Syringe Pump

Breve descripción:

Rango de flujo:

Número máximo de canales:

 

Envíenos un correo electrónico

TSD01-01 Two Way Push Pull Syringe Pump

● Lead Fluid TSD01-01 is a small flow, alta precisión, can be continuous transmission liquid syringe pump.
● Durable mechanical transmission design, long life and good reliability. Screw fixation using special high precision aviation bearing alternatives to traditional copper, longer service life and high precision.
● High resolution color LCD, touch screen is convenient fast set parameters, multiple light clear confirmed its working state.
● Support for multiple syringe to choose, to meet the requirements of different experimental flow and high precision control,and protection agencies and alarm mechanism.
● RS485 communication, Soporta el protocolo MODBUS., wide range power input, adapt to various occasions.

Características

• It can assemble two syringes, through several tube-line connection, realize continuous transmission liquid

• A variety of working mode

• Color touch screen, LCD display, convenient operation

• Sistema de software LF-Touch-OS

• Support screen lock, operación de silencio de tecla

• Button with indicator light, estado claramente de trabajo

• Support a variety of standard syringe, personalizar la jeringa

• High precision control

• Syringe protection and traffic jam alarm

• Comunicación RS485, Soporta el protocolo MODBUS.

• External signal control start-stop and direction

• wide range voltage power input

• All-metal anti-static, anti-corrosion spraying process housing

Parámetro técnico

Woke mode infuse, withdraw, infuse/withdraw, withdraw/infuse, continuous mode
Syringe size 10μL~60mL
Rango de flujo 0.184nL/min~83.318mL/min
Modo de visualización 44.3 inch color LCD, displays the transfer liquid volume, remaining liquid
volumen, tasa de flujo, running direction, syringe specifications on screen,
animation shows the running status
Modo de operación touch screen + botón de máscara
Exactitud error≤±0.35%(≥30%of pump stroke)
Linear force >20kgf,linear force adjustable
Advance per microstep 0.15625μm/μstep
Slowly moving speed 1μm/min
Fastest moving speed 150mm/min
External Control External 24V signal input control start-stop, work state signal output
Fuente de alimentación CA100~240V,50/60Hz
Ambiente temperature 5~40℃,humedad relativa<80%
Dimensión 290×205×180mm(LxWxH)

Reference Table of Syringe Specifications and Flow Rate

Syringe size Syringe ID (milímetros) Min (nL/min) máx. (ml/min)
10µL

0.485

0.184 0.027
25µL

0.729

0.417 0.0626
50µL

1.03

0.833 0.125
100µL

1.457

1.667 0.250
250µL

2.304

4.169 0.625
500µL

3.256

8.326 1.248
1mililitros

4.699

17.342 2.601
5mililitros

11.989

112.890 16.933
10mililitros

14.427

163.169 24.754
20mililitros

19.05

285.027 42.754
30mililitros

21.59

366.090 54.913
60mililitros

26.594

555.459 83.318

Schematic diagram of continuous flow principle

Los parámetros de flujo anteriores se obtienen utilizando un tubo de silicona para transferir agua pura a temperatura y presión normales., en realidad se ve afectado por factores específicos como la presión, medio, etc.. Arriba solo como referencia.

Dimensión (milímetros)

Declaración:El derecho de explicación final de la información anterior pertenece a Lead Fluid..

Leave Your Message